J Hosp Infect ; 136: 110-117, 2023 Jun.
Article in English | MEDLINE | ID: covidwho-2298590

ABSTRACT

BACKGROUND: Healthcare workers treating SARS-CoV-2 patients are at risk of infection by respiratory exposure to patient-emitted, virus-laden aerosols. Source control devices such as ventilated patient isolation hoods have been shown to limit the dissemination of non-infectious airborne particles in laboratory tests, but data on their performance in mitigating the airborne transmission risk of infectious viruses are lacking. AIM: We used an infectious airborne virus to quantify the ability of a ventilated hood to reduce infectious virus exposure in indoor environments. METHODS: We nebulized 109 plaque forming units (pfu) of bacteriophage PhiX174 virus into a ∼30-m3 room when the hood was active or inactive. The airborne concentration of infectious virus was measured by BioSpot-VIVAS and settle plates using plaque assay quantification on the bacterial host Escherichia coli C. The airborne particle number concentration (PNC) was also monitored continuously using an optical particle sizer. FINDINGS: The median airborne viral concentration in the room reached 1.41 × 105 pfu/m3 with the hood inactive. When active, the hood reduced infectious virus concentration in air samples by 374-fold. The deposition of infectious virus on the surface of settle plates was reduced by 87-fold. This was associated with a 109-fold reduction in total airborne particle number escape rate. CONCLUSION: A personal ventilation hood significantly reduced airborne particle escape, considerably lowering infectious virus contamination in an indoor environment. Our findings support the further development of source control devices to mitigate nosocomial infection risk among healthcare workers exposed to airborne viruses in clinical settings.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/prevention & control , Viral Load , Respiration, Artificial , Respiratory Aerosols and Droplets
2.
J Hosp Infect ; 119: 163-169, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1433519

ABSTRACT

BACKGROUND: While the range of possible transmission pathways of severe acute respiratory syndrome coronavirus-2 in various settings has been investigated thoroughly, most authorities have recently acknowledged the role of aerosol spread in its transmission, especially in indoor environments where ventilation is poor. Engineering controls are needed to mitigate aerosol transmission in high-risk settings including hospital wards, classrooms and offices. AIM: To assess the effectiveness of aerosol filtration by portable air cleaning devices with high-efficiency particulate air filters used in addition to a standard building heating ventilation and air conditioning (HVAC) system. METHODS: Test rooms, including a single-bed hospital room, were filled with test aerosol to simulate aerosol movement. Aerosol counts were measured over time with various portable air cleaning devices and room ventilation systems to quantify the overall aerosol clearance rate. FINDINGS: Portable air cleaning devices were very effective for removal of aerosols. The aerosols were cleared five times faster in a small control room with portable air cleaning devices than in the room with HVAC alone. The single-bed hospital room had an excellent ventilation rate (∼14 air changes per hour) and cleared the aerosols in 20 min. However, with the addition of two air cleaning devices, the clearance time was three times faster. CONCLUSIONS: Inexpensive portable air cleaning devices should be considered for small and enclosed spaces in healthcare settings, such as inpatient rooms and personal protective equipment donning/doffing stations. Portable air cleaning devices are particularly important where there is limited ability to reduce aerosol transmission with building HVAC ventilation.


Subject(s)
Air Pollution, Indoor , COVID-19 , Aerosols , Air Conditioning , Filtration , Humans , SARS-CoV-2 , Ventilation